{"product_id":"modulo-de-placa-de-distribuicao-de-energia-agras-t50-pn-301-00000-14-gerenciamento-de-alta-voltagem","title":"Agras T50 Power Distribution Board Module PN 301-00000-14 | High Voltage Management","description":"\u003ch1 dir=\"ltr\"\u003e\u003cspan\u003eAgras T50 Power Distribution Board Module PN 301-00000-14 | High Voltage Management\u003c\/span\u003e\u003c\/h1\u003e\n\n\u003ch2 dir=\"ltr\"\u003e\u003c\/h2\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eIn the design of heavy-lift remotely piloted aircraft (RPAS), power management is the cornerstone that supports both propulsion and mission systems. The\u003c\/span\u003e \u003cspan\u003ePower Distribution Board (PDB) module of the Agras T50, Part Number 301-00000-14\u003c\/span\u003e \u003cspan\u003e, is the electrical nerve center of the aircraft. In aerospace operations, failure of a distribution bus can lead to the total loss of the platform; therefore, this component is designed under stringent standards of current surge tolerance and thermal dissipation.\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp dir=\"ltr\"\u003e\u003cspan\u003eFor the Agras T50, which operates with extremely high currents to support its high-traction motors and centrifugal spray systems, the PDB acts as the critical mediator between the intelligent battery and all ESCs (Electronic Speed ​​Controllers). At\u003c\/span\u003e \u003cspan\u003eMagallan Aerospace Supply\u003c\/span\u003e \u003cspan\u003e, we treat this unique module as a flight safety item, essential to ensure that power delivery is linear, safe, and protected against electromagnetic interference.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch2 dir=\"ltr\"\u003e \u003cspan\u003eWhat it is and how it works.\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eThe PN 301-00000-14 Power Distribution Board is a high-conductivity, multi-layer unit that acts as the drone's central power hub. Its primary function is to receive the raw voltage from the battery and distribute it in a branched fashion to the aircraft's arms, radar sensors, flight controller, and payload systems.\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe operation is based on thickened copper busbars that minimize internal resistance and voltage drop\u003c\/span\u003e \u003cspan\u003e.\u003c\/span\u003e \u003cspan\u003eIn addition to power distribution, the module integrates filtering circuits that protect sensitive components against electrical noise generated by the rapid switching of brushless motors. It also acts as a communication interface, allowing current consumption telemetry data to be sent in real time to the aircraft's Central Processing Unit.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch2 dir=\"ltr\"\u003e \u003cspan\u003eOperational Applications in Aviation and Drones\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003ePower Bus Centralization\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eIt acts as the convergence point for all high-current harnesses, eliminating wiring complexity and reducing points of failure due to loose connections or excessive resistance.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003eMission Systems Protection\u003c\/span\u003e\n\u003c\/h3\u003e\n\n \u003cp dir=\"ltr\"\u003e\u003cspan\u003eIt distributes regulated low-voltage power to critical sensors, such as the Front Scanning Radar and the Binocular Vision System, ensuring that they remain active even under maximum demand from the traction motors.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3 dir=\"ltr\"\u003e \u003cspan\u003eStructural Maintenance and Repair (MRO)\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eA fundamental component in the reconstruction of aircraft that have suffered electrical damage due to overload, infiltration of corrosive liquids, or impacts that compromised the integrity of the original busbars.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch2 dir=\"ltr\"\u003e \u003cspan\u003eTechnical and Operational Benefits\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eOperational Reliability:\u003c\/span\u003e \u003cspan\u003eCircuits designed to operate under high temperature conditions without degradation of conductivity.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003ePrecision in Current Delivery:\u003c\/span\u003e \u003cspan\u003eEnsures that each ESC receives exactly the same voltage, allowing for balanced thrust and stable flight.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e \n\u003cspan\u003eReduced Thermal Failures:\u003c\/span\u003e \u003cspan\u003eOptimized layout for heat dissipation, avoiding hot spots\u003c\/span\u003e \u003cspan\u003ethat\u003c\/span\u003e \u003cspan\u003ecan lead to connector meltdown.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eSimplified Integration:\u003c\/span\u003e \u003cspan\u003eQuick-connect ports and reinforced solder points that follow the OEM standard for a\u003c\/span\u003e \u003cspan\u003edrop-in\u003c\/span\u003e replacement \u003cspan\u003e.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003ePerformance Optimization:\u003c\/span\u003e \u003cspan\u003eThe low impedance of the plate improves the efficiency of the propulsion system, resulting in marginal, yet critical, gains in flight range.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 dir=\"ltr\"\u003e \u003cspan\u003eKey Technical Differentiators\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eReinforced Layered Construction:\u003c\/span\u003e \u003cspan\u003eIndustrial-grade PCB with multiple layers of high-grammage copper to withstand current surges during evasive maneuvers.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e \n\u003cspan\u003eConformal Coating:\u003c\/span\u003e \u003cspan\u003eProtective layer against moisture and chemical corrosion (fertilizers and pesticides), essential for longevity in harsh agricultural environments.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eHigh Amperage Connectors:\u003c\/span\u003e \u003cspan\u003eTerminals designed to support the T50 system battery connections without generating an electric arc or contact resistance.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eSignal Isolation:\u003c\/span\u003e \u003cspan\u003ePhysical separation between high-power traces and data traces, preventing corruption of command signals (EMI).\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 dir=\"ltr\"\u003e \u003cspan\u003eTechnical Specifications\u003c\/span\u003e \u003c\/h2\u003e\n\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\n\u003ctable\u003e\n\n\u003ccolgroup\u003e\n\n\u003ccol width=\"219\"\u003e\n\n\u003ccol width=\"363\"\u003e\n\n\n\u003c\/colgroup\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eTechnical Detail\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003ePower Distribution Board (PDB Module)\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eMagallan Approved \/ Original Series\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003ePart Number (PN)\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003e301-00000-14\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eCategory\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eElectronics \u0026amp; Flight Control\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eMain Application\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eAgras T50 Power Distribution\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n \u003cp dir=\"ltr\"\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eCompatible with 14S - 18S (LiPo\/Li-ion) systems.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eHigh Current Terminals \/ Signal Sockets\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eEnvironmental Protection\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eChemical Corrosion Resistant Coating\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e\n\n\u003cp dir=\"ltr\"\u003e \u003cspan\u003e-10°C to 60°C\u003c\/span\u003e \u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eCompatibility and Installation Requirements\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eTarget Aircraft:\u003c\/span\u003e \u003cspan\u003eExclusive to Agras T50.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eInstallation Requirements:\u003c\/span\u003e \u003cspan\u003eRequires partial disassembly of the central fairing and cooling module. The use of antistatic tools is recommended, as well as rigorous verification of all power connection screw torques.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eSynchronization:\u003c\/span\u003e \u003cspan\u003eAfter installation, it is recommended to check the voltage telemetry via the control application to ensure that all distribution channels are operating within nominal parameters.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eImportant Technical Guidelines and Considerations\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003col\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eConnector Inspection:\u003c\/span\u003e \u003cspan\u003eBefore closing the aircraft, check for any metallic debris or solder residue on the board, which could cause a catastrophic short circuit.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eProtective Handling:\u003c\/span\u003e \u003cspan\u003eBecause this is an electronic component sensitive to ESD (Static Electricity), it should only be handled by its edges and with a grounding wrist strap.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\n \u003cspan\u003eLeakage Check:\u003c\/span\u003e \u003cspan\u003eEnsure that the seal of the drone's central compartment is restored after the board replacement to maintain the aircraft's nominal IP protection.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ol\u003e","brand":"Magallan Aerospace","offers":[{"title":"Default Title","offer_id":47616898957486,"sku":null,"price":2500.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0738\/0615\/1854\/files\/detalhe-conectores-alta-corrente-pdb-agras-t50.jpg?v=1772913445","url":"https:\/\/www.magallanaerospace.com\/en\/products\/modulo-de-placa-de-distribuicao-de-energia-agras-t50-pn-301-00000-14-gerenciamento-de-alta-voltagem","provider":"Magallan Aerospace","version":"1.0","type":"link"}